Britpart Dual Battery Management System Part No. DA1174

  • Order online today
  • International delivery available
  • Secure online payment
  • Available:
    This item is available for dispatch.
Now £244.22 exc. VAT
£293.06 inc. VAT
Shipping Dimensions:
  • Length: 22cm / 220mm
  • Width: 9.5cm / 95mm
  • Height: 8cm / 80mm
  • Courier Packing Size: 57 box3
  • Weight: 0.77kg
Found a discrepancy? Contact Us

Britpart Dual Battery Management System DA1174

Enhance your Land Rover's electrical reliability with the Britpart DA1174 Dual Battery Management System. Designed for vehicles requiring auxiliary powersuch as those equipped with winches, fridges, or off-grid equipmentthis Swiss-made, microprocessor-controlled system ensures seamless integration of dual battery setups. It automatically separates the starter battery from the auxiliary battery when the vehicle is off, preventing drain, and links them during engine operation for efficient charging. This intelligent management optimizes battery health and extends lifespan.


The system features a 200A power relay and offers manual override functions for emergency situations or high-power demands. The included battery monitor provides real-time voltage readings and alerts for low battery levels or link failures, ensuring you're always informed about your vehicle's electrical status. With a comprehensive wiring loom and sealed automotive connectors, installation is straightforward, making it suitable for both professional and DIY installations.


Key Highlights:
  • Automatic Battery Management: Seamlessly separates and links batteries based on engine status, protecting battery health.
  • Manual Override Function: Provides 30- and 120-minute manual linking options for emergency or high-power needs.
  • Real-Time Monitoring: Dashboard-mounted display offers continuous voltage readings and alerts for both batteries.

    Separates the starter battery from auxiliary battery if the vehicle has stopped and links them while the car is running.

    This fully automatic Swiss made Microprocessor Controlled Dual Battery Management System separates the starter battery from auxiliary battery if the vehicle has stopped and links them while the car is running. All systems are equipped with a 200A power relay. For emergency situations all systems are equipped with the manual override function (link). This manual linking function (called load sharing) is very helpful for jump starting or when using high current appliances such as an electrical recovery winch, power inverter or compressor. The kit includes a 4.7m wiring loom with sealed automotive plug, battery and crimp terminals for easy installation.
    The battery monitor is installed in the vehicle (dash) and informs the driver about the charge level of both batteries, the charging voltage from the alternator or an additionally installed solar system and the relay link status. The system offers low battery alarm on both batteries and a link failure alarm. Includes a manual link for 30 and 120 minutes with automatic return.

    Functions
    Display of Battery Voltage (Energy Level)
    LED indicators:
    Green: Batteries are in the safe working range
    Yellow: Check batteries
    Red: Batteries should be charged
    The LED’s show the energy level if all loads are switched off:
    12.6V = 100%
    12.4V = 75%
    12.2V = 50%
    12.0V = 25%
    11.0V = flashing and beeping indicates low battery situation
    This function is called by pressing the display button for about 30 seconds.

    Display of Charge Voltage while charging
    LED indicators:
    Red: >14.5V: High loading of batteries, may be present at cold ambient temp. for a longer time.
    Yellow: >14.0V: Proper charge mode.
    Green: <14.0V: Save charge mode, no damage to batteries.

    Bi-directional Automatic Battery link
    While the engine is running the main and auxiliary batteries are linked together for parallel charging from the alternator (green LED linked is on). If the engine is stopped, the two batteries will be disconnected automatically with some delay. Appliances as fridges, lights, compressors, inverters are now safely fed from the auxiliary battery. With the additional charge by solar equipment, battery charger or generator is sufficient for charging, the starter battery will be charged automatically with auxiliary battery together (green LED "link" lights).

    Manual Battery "link"
    In an emergency situation (defective or empty main battery) or in case of higher power consumption the two batteries (main & auxiliary) may be connected together by activating the link button (red LED manually linked is on) After a lapse of time of 30 minutes (or immediately after activating the auto button), the system returns to the automatic mode. When using an electric winch, the battery connection can be activated for 120 minutes by pressing the link button twice. In this mode a beep sounds every 30 seconds to indicate this status (auto return after time expired). The load sharing function with the manual battery connection reduces the load on the alternator, the wiring and the batteries in the use of the winch.

    Alarm functions:
    Low battery alarm
    If the battery voltage of one or both of the batteries, is for a longer period below 12V, the sound low battery with "Beep" and the LED "Low Battery" of the corresponding battery (main and / or auxiliary) flashes. With the display button, the "Beep" is switched off. The blinking LED "Low Battery" is reset if the battery voltage is exceeding 12V.

    Link failure alarm
    The monitor monitors the charge on both batteries. When fitting charge (from alternator, solar, charger) no charge to the other battery is detected, the link error alarm with flashing green LED "linked" and the “Beep” sounds. If this error occurs, check immediately the wiring of the power cables to (relay, battery terminals, crimp contacts, control relays). After bug fixes, alarm will automatically reset.

    Deactivation of automatic and manual battery dual link function
    If there is a problem with the auxiliary battery (aux) as short circuit of cells, short circuit or defective battery housing, leading to damage of the generator (alternator). In an emergency situation the battery system can be operated in the vehicle in the basic configuration (alternator, starter battery without additional charge to auxiliary battery). By pressing the link button for 6 seconds (until the sound of the beep), the link is deactivated. In this mode, no manual and automatic battery connection is possible. This feature can solve the battery problem of the auxiliary battery by pressing the auto button for 6 seconds to be reset. Now the system is working again with all the functions.

    Specifications
    Supply voltage: 4 - 16V

    System voltage: 12V

    Measuring range (sense wire blue): 8 - 16V

    Display range (battery voltage): 11.0V - 12.8V

    Alarm level main and aux: 12.0V

    Display range (charge): 13.0V - 14.5V

    Accuracy: +/-1%

    Consumption monitor: 1mA

    Consumption max. display active (30 sec): 20mA

    Isolator link-on/off threshold: 13.1V/13.0V

    Consumption on-state (relay): 0.6A

    Relay continuous load current: 200A

    Relay current inrush: 500A

    Relay contact material: Silver (AG SnO2)

    Free combination of batteries possible?: Yes

    Operating temperature: -40°C - +80°C

    Housing: ABS black

    Sealing level: IP40

    Size, dimensions: 100 x 65 x 24mm

    Weight: 800g

    Cabling:
    Red - Supply/sense (main battery)
    Black - GND (main battery)
    Blue - Sense (aux battery)
    Green - Control relay (open collector)

    Protected against:
    Against wrong polarity
    Against overload of solenoid driving circuit on PC board with SMD electronically security devices, no fuses have to be replaced